  • Portable Lighting Detection Instrument (HSM)
    Portable Lighting Detection Instrument (HSM)
    HSM-01, HSM-02, HSM-21

    Rainbow-Light launches protable LED Light Measuring Instrument for lighting cource spectral measurement products, manufactured by Microelectromechanical Technology, is different from tranditional spectrometer with complicated optical components. MEMS Micro-spectrometer (RLS) is using the manufacturing procedure of "concave grating" replaced with traditional spectrometer consisted of collimating mirror, flat grating and focusing mirror as to has the features of anti-shocking, low calibration demands, cost-effective, extra small size, portable and so on.


  • LED Luminous Decay Monitoring Instrument (LDM)
    LED Luminous Decay Monitoring Instrument (LDM)
    LDM-01, LDM-02, LDM-21

    Rainbow-Light launches LED Luminous Decay Dectection Meter (LDM) which can measure and monitor Luminous Intesity, Lumen Decay, CCT, CRI, Illuminance etc...precisely.


  • Portable Lighting Measuring Instrument with Display
    Portable Lighting Measuring Instrument with Display
    MR-16

    Rainbow-Light launches Portable Lighting Measuring Equipment with Display, manufactured by Microelectromechanical Technology as to has the features of small size, anti-vibration, anti-shocking and portable. Due to excellent and stable quality and low calibration demands, that can save lot of money in repair or correction.


  • Goniophotometer (CDM)
    Goniophotometer (CDM)
    CDM-01, CDM-02, CDM-21

    Rainbow-Light, light source spectrum measurement for product launch lamp, light distribution curve instrument (CDM), the light distribution is light intensity in each direction space lighting, available data and graphic display. The data and graphics of the light distribution can help us understand the light distribution of the lighting lamp, and the data itself is the basis for calculating the lighting rate, illuminance, brightness, distance ratio, luminaire efficiency and glare level


  • Full Spectrum Transmittance Measuring Instrument (TSM)
    Full Spectrum Transmittance Measuring Instrument (TSM)
    TSM-01, TSM-02, TSM-21, TSM-12

    Rainbow-Light launches Full Spectrum Transmittance Measuring Equipment (TSM) for the wavelength range of 300 - 1100 nm. The parameters measured are mainly including anti-UV index, visible transmittance rate and visible transmittance evenness. Integrating Sphere can be optional for Haze Measurement.


  • Full Spectrum Transmittance Measuring Instrument, Full-function, TSM-01
    Full Spectrum Transmittance Measuring Instrument, Full-function, TSM-01
    TSM-01

    There are four models of Full Spectrum Transmittance Measuring Instrument (TSM), named TSM-01 (Full-function), TSM-02 (Regular), TSM-21 (High sensitivity), TSM-12(Touch panel). TSM-01 (Full-function) for the wavelength range of 300 - 1100 nm. The parameters measured are mainly including anti-UV index, visible transmittance rate and visible transmittance evenness. Integrating Sphere can be optional for Haze Measurement.


  • Full Spectrum Transmittance Measuring Instrument, Regular, TSM-02
    Full Spectrum Transmittance Measuring Instrument, Regular, TSM-02
    TSM-02

    There are four models of Full Spectrum Transmittance Measuring Instrument (TSM), named TSM-01 (Full-function), TSM-02 (Regular), TSM-21 (High sensitivity), TSM-12(Touch panel). TSM-02 (Regular) for the wavelength range of 380 - 780 nm. The parameters measured are mainly including visible transmittance rate and visible transmittance evenness. Integrating Sphere can be optional for Haze Measurement.


  • Full Spectrum Transmittance Measuring Instrument, High sensitivity, TSM-21
    Full Spectrum Transmittance Measuring Instrument, High sensitivity, TSM-21
    TSM-21

    There are four models of Full Spectrum Transmittance Measuring Instrument (TSM), named TSM-01 (Full-function), TSM-02 (Regular), TSM-21 (High sensitivity), TSM-12(Touch panel). TSM-21 (High sensitivity) for the wavelength range of 300 - 1100 nm. The parameters measured are mainly including anti-UV index, visible transmittance rate and visible transmittance evenness. Integrating Sphere can be optional for Haze Measurement.


  • Full Spectrum Transmittance Measuring Instrument, Touch panel, TSM-12
    Full Spectrum Transmittance Measuring Instrument, Touch panel, TSM-12
    TSM-12

    There are four models of Full Spectrum Transmittance Measuring Instrument (TSM), named TSM-01 (Full-function), TSM-02 (Regular), TSM-21 (High sensitivity), TSM-12(Touch panel). TSM-12 (Touch panel) for the wavelength range of 380 - 780 nm. The parameters measured are mainly including visible transmittance rate and visible transmittance evenness. Integrating Sphere can be optional for Haze Measurement.


  • 380 ~ 780 nm, Visible Light Micro Spectrometer (CVSLS-VLS)
    380 ~ 780 nm, Visible Light Micro Spectrometer (CVSLS-VLS)
    CVSLS-1000, VLS-1000

    Any material for different wavelengths of light absorption of different degrees, namely the extinction coefficient or molar extinction coefficient also differs by wavelength. Because of a variety of pure substances (compounds and elements) each has its unique spectrum, as each person's fingerprints, so the spectrum location by absorption wavelength of light can distinguish samples ingredients. Even if it is not transparent to visible light absorption material, and also by the infrared, ultraviolet visible spectrum not obtained, identify identified. Bill's law, also known as Bill (Beer-Lambert Law), Lambert's law is a fundamental law. When the optical light penetrates the sample solution, the absorption of light (A) and absorption coefficient (alpha), optical path length (L), concentration (c) three were proportional to the A = of a LC, including: alpha absorption coefficient (absorptivity, absorption or coefficient), also known as the extinction coefficient (extinction coefficient, K). The absorption of A for a greater than or equal to zero real, usually falls on the 0 to 2, where 0 represents no absorption, 2 represents ninety-nine percent of the light is absorbed by. But "the absorption rate" (absorptance) coefficients are often used. The absorption rate is usually represented by a lowercase print, said the solution of light absorption ratio, so the absorption rate and absorption absorption is different, used to replace Bill's law in the absorption rate. Rainbow-Light, the absorption measurement of product launch, visible micro spectrometer (CVSLS-VLS), MEMS in MEMS manufacturing technology, has small volume, seismic resistance and portability. The visible micro spectrometer (CVSLS-VLS). The stability is good, the calibration demand is low, and many expensive correction fees can be saved every year, while the FWHM (0.8 ~ 1.5 nm) is high.


  • 200 ~ 800 nm, Ultra-Violet Micro Spectrometer
    200 ~ 800 nm, Ultra-Violet Micro Spectrometer
    UVLS-1000

    Any material for different wavelengths of light absorption of different degrees, namely the extinction coefficient or molar extinction coefficient also differs by wavelength. Because of a variety of pure substances (compounds and elements) each has its unique spectrum, as each person's fingerprints, so the spectrum location by absorption wavelength of light can distinguish samples ingredients. Even if it is not transparent to visible light absorption material, and also by the infrared, ultraviolet visible spectrum not obtained, identify identified. Bill's law, also known as Bill (Beer-Lambert Law), Lambert's law is a fundamental law. When the optical light penetrates the sample solution, the absorption of light (A) and absorption coefficient (alpha), optical path length (L), concentration (c) three were proportional to the A= of a LC, including: alpha absorption coefficient (absorptivity, absorption or coefficient), also known as the extinction coefficient (extinction coefficient, K). The absorption of A for a greater than or equal to zero real, usually falls on the 0 to 2, where 0 represents no absorption, 2 represents ninety-nine percent of the light is absorbed by. But "the absorption rate" (absorptance) coefficients are often used. The absorption rate is usually represented by a lowercase print, said the solution of light absorption ratio, so the absorption rate and absorption absorption is different, used to replace Bill's law in the absorption rate. In the light of Rainbow-Light, the absorption rate of products, launched the UV-Visible-Near infrared band micro spectrometer (VLS-1000), MEMS in MEMS manufacturing technology, has small volume, seismic resistance and portability. The UV-Visible-Near-infrared band micro optical spectrum analyzer (VLS-1000) excellent stability, correction of low demand every year can save a lot of expensive correction costs, also has a high resolution (0.8~1.5 nm FWHM). In the light of Rainbow-Light ultraviolet / visible / near-infrared band micro spectrometer (VLS-1000) spectra of deviation of plus or minus 0.1 Naiminei, stability testing data also fell within 4/10000 of the standard, and adapt to various environments. In the light of Rainbow-Light ultraviolet / visible / near-infrared band micro spectrometer (VLS-1000) wide spectral range, high resolution, ultra small size, low setup cost, programmable controller design, USB interface without external power. Collocation integral ball, optical fiber, optical fiber sleeve, Y type, angle analyzer etc. surrounding the application. In the light of Rainbow-Light ultraviolet / visible / near-infrared band micro spectrometer (VLS-1000) is very suitable for carrying out to various environments, real-time sampling real time measurement, effectively solve the time waiting for the laboratory to make the sample changes the measurement uncertainty.


  • 45° Reflectance Measuring Instrument (RLT)
    45° Reflectance Measuring Instrument (RLT)
    RLT-01, RLT-02, RLT-21

    Rainbow-Light launched 45 degree reflectance measurement products (RLT) by MEMS manufacturing technology which has the advantages of small size, anti-seismic, anti-shocking, portability, excellent stability, low correction demands to save a lot of costs in correction and high resolution (0.8~1.5 nm FWHM). 45 degree reflectance measuring instrument (RLT) spectral deviation is plus or minus 0.1 nm. Stability testing data also is within 4/10000 of the standard. It adapts to various environments. 45 degree reflectance measuring instrument (RLT) can test items: UV, visible light reflectivity, ultraviolet light measurement, deuterium lamp as light source, and show the full spectrum test data


  • Full Spectrum Color Measuring Instrument
    Full Spectrum Color Measuring Instrument
    CS-16

    Rainbow-Light launched portable full spectrum color measurement instrument (CS-16) for the reflectance measurement, color measurement products by using MEMS manufacturing technology as to has small volume, seismic resistance and portability. This is designed for fast measurement of paper, paint, plastics and textiles color data.


  • Desktop Full Spectrum Color Meter (CMM)
    Desktop Full Spectrum Color Meter (CMM)
    CMM-01, CMM-02

    Rainbow-Light full spectrum color measurement instrument (CMM) can instantly display color L*a*b*, Delta E, Delta Lab, CIE X, CIE Y, CIE 1976 measurements.


  • Case 1. Bio-Chip Automatic Measuring Instrument
    Case 1. Bio-Chip Automatic Measuring Instrument
    TSM-21

    Rainbow-Light,’s customized products are based on full spectrum transmittance measurement instrument (TSM) and architecture based on the specific absorption spectrum analysis is the core of measuring system of customized automatic biochip. As the core of micro spectrometer, Rainbow-Light can produce and supply all kinds of customized full spectrum transmittance rate measuring instrument by utilizing microelectromechanical (MEMS) and the exclusive “dynamic thermal equilibrium (DTE)” technology. Spectral deviation is within plus or minus 0.1 nm. The stability of testing data is in 0.04% and accommodates to vibration environment, environment temperature changes (the applicable temperature range of -10 DEG C~50 DEG C; 0.02nm/ C). Our systems can match the customized software to measure spectrum, absorbance, reflectance, transmittance, etc.. Welcome your enquiry by e-mail or phone calling for various customized products and services.


  • Case 2. Desktop Light Flux Integrating Sphere System
    Case 2. Desktop Light Flux Integrating Sphere System
    LSM-06

    Rainbow-Light, aiming at customized products, based on luminous flux integrating ball system (LSM-05/06), the customer meets the customer's integral integration ball system mechanism. In the light of Rainbow-Light in application, can be customized to any form of full spectrum transmittance measuring instrument, using microelectromechanical (MEMS) and exclusive "dynamic thermal balance (DTE) technique, the micro spectrometer as the core and made. Spectral deviation of plus or minus 0.1 nm, stability testing data also fell in 0.04% within the standard, and adapt to the environment under the operation, is suitable for vibration environment, environment temperature changes (the applicable temperature range of -10°C ~ 50°C; 0.02nm/°C). The system can be used with custom software to carry out various spectral measurements, applications and analysis. Welcome calls from all walks of life to inquire about the customized service of our products.


  • Case 3. DNA Measuring Instrument
    Case 3. DNA Measuring Instrument
    Deuterium Lamp

    Rainbow-Light, for customized products, share customized DNA measurement instrument and deuterium lamp group. In the light of Rainbow-Light in application, can be customized to any form of full spectrum transmittance measuring instrument, using microelectromechanical (MEMS) and exclusive "dynamic thermal balance (DTE) technique, the micro spectrometer as the core and made. Spectral deviation of plus or minus 0.1 nm, stability testing data also fell in 0.04% within the standard, and adapt to the environment under the operation, is suitable for vibration environment, environment temperature changes (the applicable temperature range of -10°C ~ 50°C; 0.02nm/°C). The system can match the guest software and carry out the spectral measurement, absorbance, absorptivity, reflectivity, penetration, etc., measurement, application and analysis. Welcome calls from all walks of life to inquire about the customized service of our products.


  • Case 4. Handheld Full Spectrum Color Meter
    Case 4. Handheld Full Spectrum Color Meter
    CS-16

    Rainbow-Light, based on the handheld full spectrum color meter (CS-16), a handheld hand-held full spectrum color measurement apparatus and software for guest products. In the light of Rainbow-Light in application, can be customized to any form of full spectrum transmittance measuring instrument, using microelectromechanical (MEMS) and exclusive "dynamic thermal balance (DTE) technique, the micro spectrometer as the core and made. Spectral deviation of plus or minus 0.1 nm, stability testing data also fell in 0.04% within the standard, and adapt to the environment under the operation, is suitable for vibration environment, environment temperature changes (the applicable temperature range of -10°C ~ 50°C; 0.02nm/°C). The system can match the guest software for spectral measurement, reflectivity, color analysis, etc. measurement, application and analysis. Welcome calls from all walks of life to inquire about the customized service of our products.


  • Case 5. Water Monitoring System
    Case 5. Water Monitoring System

    Rainbow-Light, for customized products, the use of industrial 4, light / color / water / liquid system for real time monitoring technology, customized installation quality monitoring system. In the light of Rainbow-Light in application, can be customized to any form of full spectrum transmittance measuring instrument, using microelectromechanical (MEMS) and exclusive "dynamic thermal balance (DTE) technique, the micro spectrometer as the core and made. Spectral deviation of plus or minus 0.1 nm, stability testing data also fell in 0.04% within the standard, and adapt to the environment under the operation, is suitable for vibration environment, environment temperature changes (the applicable temperature range of -10°C ~ 50°C; 0.02nm/°C). The system can be used with guest software for spectral monitoring, absorbance, absorbance, reflectivity, penetration, etc. monitoring, application and analysis. Welcome calls from all walks of life to inquire about the customized service of our products.


  • Case 6. Plant Illumination Monitoring and Controlling System
    Case 6. Plant Illumination Monitoring and Controlling System

    Rainbow-Light, for customer products, intelligent plant growth, real-time monitoring system, customized design, manufacture, installation. In the light of Rainbow-Light in application, can be customized to any form of full spectrum transmittance measuring instrument, using microelectromechanical (MEMS) and exclusive "dynamic thermal balance (DTE) technique, the micro spectrometer as the core and made. Spectral deviation of plus or minus 0.1 nm stability testing data also fell in 0.04% within the standard, and adapt to the environment under the operation, is suitable for vibration environment, environment temperature changes (the applicable temperature range of -10°C ~ 50°C; 0.02nm/°C). The system can be configured with guest software for spectral monitoring, LED light source, spectral control, etc. monitoring, application, and analysis control. Welcome calls from all walks of life to inquire about the customized service of our products.


  • Spectral Analysis of Related Testing Service
    Spectral Analysis of Related Testing Service

    Rainbow-Light in R&D and products have been affirmed and introduced the quality concept of ISO / IEC 17025 in the laboratory operation and execute stringent quality requirements of environment, equipment, detection methods, report audit and production. Rainbow-Light Laboratory has a wide range of spectral correlation analysis instrument, including various specifications of the spectrometer, integrating sphere system of various sizes, remittance rate measuring instrument, reflectance measuring instrument, absorbance measuring instrument, goniophotometer, light decay measuring instrument, spectral standard calibration light, spectrum measurement chamber and so on... complete spectral analysis of related equipment. Spectral testing services are including light decay, flux/lumen, transmittance rate, spectrum, light distribution curve, fluorescent reaction tests, absorption tests, DNA protein concentration tests, identification of methanol and ethanol, surface treatment of metal, film, reflectance rate... . Please contact us by e-mail or call us directly for details. Thank you!



Result 1 - 21 of 21